MD ET-2 Internal Side stream EtCo2 module
Intelligent design can wipe off the excursion from temperature, pressure and inconsistent component.
Intelligent design can wipe off the excursion from temperature, pressure and inconsistent component.
It allows wrong power supply, humidity in the pipeline.
Great capacity to ensure that any provision of about 50 sets of stock
TTL or RS232 can be choice by customer.
Intelligent design can wipe off the excursion from temperature, pressure and inconsistent component.
It allows wrong power supply, humidity in the pipeline.
Great capacity to ensure that any provision of about 50 sets of stock
TTL or RS232 can be choice by customer.
Safety ETCO2:BF type
Power Requirements 12.0V±0.2V DC
Power Consumption 100mA (typical with pump on) 200mA (extreme status)
Operating Temperature Range 5~50℃
Shipping/Storage Temperature Range -20~+70℃
Relative Humidity 0-85% (non-condensing)
Dimensions 96×91×36mm
CO2 Range 0 to 13%(0-98.8mmHg@BTPS)
CO2 Accuracy <5.0% CO2 (at BTPS) ± 3 mmHg
>5.0% CO2 (at BTPS) < 10% of reading
Breath Rate 3~60 BPM
Measurement Accuracy ±1BPM
Warm-up Time 10 seconds
Response Time Detector: 10mS,
System: Dependent Upon Implementation, Pneumatics
and Water Separation Technique
Flow Control 50~250ml/min
Interface Highly configurable serial digital interface (TTL/RS232)
Automatic Offset Calibration Time and temperature based, as well as on-demand
Options:
CO2 Sample Line
Nasal TubeCO2 Sample Line
Power Adapter
Water-trap Column
Airway Adapter
Product Features
Intelligent design can wipe off the excursion from temperature, pressure and inconsistent component.
It allows wrong power supply, humidity in the pipeline.
Great capacity to ensure that any provision of about 50 sets of stock
TTL or RS232 can be choice by customer.
Product Specifications
Safety ETCO2:BF type
Power Requirements 12.0V±0.2V DC
Power Consumption 100mA (typical with pump on) 200mA (extreme status)
Operating Temperature Range 5~50℃
Shipping/Storage Temperature Range -20~+70℃
Relative Humidity 0-85% (non-condensing)
Dimensions 96×91×36mm
CO2 Range 0 to 13%(0-98.8mmHg@BTPS)
CO2 Accuracy <5.0% CO2 (at BTPS) ± 3 mmHg
>5.0% CO2 (at BTPS) < 10% of reading
Breath Rate 3~60 BPM
Measurement Accuracy ±1BPM
Warm-up Time 10 seconds
Response Time Detector: 10mS,
System: Dependent Upon Implementation, Pneumatics
and Water Separation Technique
Flow Control 50~250ml/min
Interface Highly configurable serial digital interface (TTL/RS232)
Automatic Offset Calibration Time and temperature based, as well as on-demand