ET-2 Internal Side stream EtCo2 module
MD ET-2 Internal Side stream EtCo2 module
Intelligent design can wipe off the excursion from temperature, pressure and inconsistent component.

It allows wrong power supply, humidity in the pipeline.
Great capacity to ensure that any provision of about 50 sets of stock
TTL or RS232 can be choice by customer.
MD ET-2 Internal Side stream EtCo2 module
Intelligent design can wipe off the excursion from temperature, pressure and inconsistent component.

It allows wrong power supply, humidity in the pipeline.
Great capacity to ensure that any provision of about 50 sets of stock
TTL or RS232 can be choice by customer.
Read More

Intelligent design can wipe off the excursion from temperature, pressure and inconsistent component.
It allows wrong power supply, humidity in the pipeline.
Great capacity to ensure that any provision of about 50 sets of stock
TTL or RS232 can be choice by customer.
 


Safety ETCO2:BF type
Power Requirements 12.0V±0.2V DC 
Power Consumption 100mA (typical with pump on)  200mA (extreme status)
Operating Temperature Range 5~50℃
Shipping/Storage Temperature Range -20~+70℃
Relative Humidity 0-85% (non-condensing)
Dimensions 96×91×36mm
CO2 Range 0 to 13%(0-98.8mmHg@BTPS)
CO2 Accuracy <5.0% CO2 (at BTPS) ± 3 mmHg
                         >5.0% CO2 (at BTPS) < 10% of reading
Breath Rate 3~60 BPM
Measurement Accuracy ±1BPM 
Warm-up Time 10 seconds
Response Time Detector: 10mS,
System: Dependent Upon Implementation, Pneumatics 
and Water Separation Technique
Flow Control 50~250ml/min
Interface Highly configurable serial digital interface (TTL/RS232)
Automatic Offset Calibration Time and temperature based, as well as on-demand
Options:

CO2 Sample Line
Nasal Tube
Power Adapter
Water-trap Column
Airway Adapter

Product Features

    
    
    Intelligent design can wipe off the excursion from temperature, pressure and inconsistent component.
    It allows wrong power supply, humidity in the pipeline.
    Great capacity to ensure that any provision of about 50 sets of stock
    TTL or RS232 can be choice by customer.
     

Product Specifications

    
    
    
    
    Safety ETCO2:BF type
    Power Requirements 12.0V±0.2V DC 
    Power Consumption 100mA (typical with pump on)  200mA (extreme status)
    Operating Temperature Range 5~50℃
    Shipping/Storage Temperature Range -20~+70℃
    Relative Humidity 0-85% (non-condensing)
    Dimensions 96×91×36mm
    CO2 Range 0 to 13%(0-98.8mmHg@BTPS)
    CO2 Accuracy <5.0% CO2 (at BTPS) ± 3 mmHg
                             >5.0% CO2 (at BTPS) < 10% of reading
    Breath Rate 3~60 BPM
    Measurement Accuracy ±1BPM 
    Warm-up Time 10 seconds
    Response Time Detector: 10mS,
    System: Dependent Upon Implementation, Pneumatics 
    and Water Separation Technique
    Flow Control 50~250ml/min
    Interface Highly configurable serial digital interface (TTL/RS232)
    Automatic Offset Calibration Time and temperature based, as well as on-demand

Related Accessories

    Options:

    CO2 Sample Line
    Nasal Tube
    Power Adapter
    Water-trap Column
    Airway Adapter

Related items

MEDITECH LIBRARY