Oxima® 2
Oxima® 2 offering highly efficient Tabletop Pulse Oximeter .
Incorporating advanced technology, Tabletop Pulse Oximeter offers excellent performance. Further, our Tabletop Pulse Oximeter is highly acclaimed for its arouses

Oxima® 2 can be applied in the hospital's operation room ICU clinic section office
Out-patient department sickroom and emergency treatment.
Oxima® 2 offering highly efficient Tabletop Pulse Oximeter .
Incorporating advanced technology, Tabletop Pulse Oximeter offers excellent performance. Further, our Tabletop Pulse Oximeter is highly acclaimed for its arouses

Oxima® 2 can be applied in the hospital's operation room ICU clinic section office
Out-patient department sickroom and emergency treatment.
Read More
Efficient performance
Easy to use
Four parameters: NIBP. SpO2. Pulse Rate. Temperature
Suitable for adult pediatric and neonatal
Battery capacity indicator and prompt when battery low
Large screen : SpO2 PR are shown on LED screen Pleth waveform is displayed on 2.8" color LCD screen in real time
24 hours or AC power and Built-in rechargeable Li-ion battery up to 5 hour running time
Storage/Review trend data up to 3888 groups data save time interval settable
Automatic shutdown for power saving shutdown time interval settable
Audio and visual alarm when parameters exceeded and sensor-off
Unique software for telemonitoring by transmitting data synchronously via internet via USB to connect with the computer 

Options
Bluetooth Printer for Oxima2
Applications: 
PC software for Oxima2
 
 
Oxima2 Vital signs monitor four parameters: NIBP SpO2 TEMP and Pulse Rate 
 
NIBP: 
Measurement method: Oscillometric 
Range: Adult: 30mmHg~255mmHg Pediatric: 30mmHg~160mmHg 
Measurement unite: MmHg/kPa selectable 
Measurement mode: Manual Auto STAT 
Measurement Type: SYS DIA MAP 
Measurement interval in AUTO mode: 1 2 3 5 10 15 20 30 45 60Min 
Measuring period in STAT mode: 5 Min 
Resolution: 1mmHg 
Over-pressure protection: Adult: 300mmHg Pediatric: 220mmHg 
 
SpO2
Range: 0 -100% 
Resolution: 1 % 
Accuracy: 2% (90~99%) 3% (70~89%) unspecified (< 70%) 
 
PR
Range: 30bpm~250bpm 
Resolution: 1bpm 
Accuracy: 2bpm 
Temperature: 
Channel: 1 
Input: Body surface thermal-sensitive resistor temperature sensor 
Measurement Unit: C/° F selectable 
Range: 0~50 
Resolution: 0.1 
Accuracy: 0.1 
Environment: 
 
Temperature 
Operation: 0C~45 
Transportation and storage: -20C~60C 
Humidity 
Operation: 15%~95% (non-condensing) 
Transportation and storage: 10%~95% (non-condensing) 
Altitude 
Operation: 86kPa ~ 106kPa 
Transportation and storage: 50kPa~106kPa 
 
Power Requirements: 
AC power adaptor 
Input: AC 100~240V 50/60Hz 0.7A 
Output: 5V 2.5A 
Internal battery 
Type: 2.8A build-in Li-ion rechargeable battery 
Operating Time: 5 hours of stand-by time with a full battery. 
Recharge time: 8 hours 
 
Dimension: 280mm × 190mm × 100mm 
Net Weight: 1000g
 

Product Features

    Efficient performance
    Easy to use
    Four parameters: NIBP. SpO2. Pulse Rate. Temperature
    Suitable for adult pediatric and neonatal
    Battery capacity indicator and prompt when battery low
    Large screen : SpO2 PR are shown on LED screen Pleth waveform is displayed on 2.8" color LCD screen in real time
    24 hours or AC power and Built-in rechargeable Li-ion battery up to 5 hour running time
    Storage/Review trend data up to 3888 groups data save time interval settable
    Automatic shutdown for power saving shutdown time interval settable
    Audio and visual alarm when parameters exceeded and sensor-off
    Unique software for telemonitoring by transmitting data synchronously via internet via USB to connect with the computer 

    Options
    Bluetooth Printer for Oxima2
    Applications: 
    PC software for Oxima2
     
     

Product Specifications

    Oxima2 Vital signs monitor four parameters: NIBP SpO2 TEMP and Pulse Rate 
     
    NIBP: 
    Measurement method: Oscillometric 
    Range: Adult: 30mmHg~255mmHg Pediatric: 30mmHg~160mmHg 
    Measurement unite: MmHg/kPa selectable 
    Measurement mode: Manual Auto STAT 
    Measurement Type: SYS DIA MAP 
    Measurement interval in AUTO mode: 1 2 3 5 10 15 20 30 45 60Min 
    Measuring period in STAT mode: 5 Min 
    Resolution: 1mmHg 
    Over-pressure protection: Adult: 300mmHg Pediatric: 220mmHg 
     
    SpO2
    Range: 0 -100% 
    Resolution: 1 % 
    Accuracy: 2% (90~99%) 3% (70~89%) unspecified (< 70%) 
     
    PR
    Range: 30bpm~250bpm 
    Resolution: 1bpm 
    Accuracy: 2bpm 
    Temperature: 
    Channel: 1 
    Input: Body surface thermal-sensitive resistor temperature sensor 
    Measurement Unit: C/° F selectable 
    Range: 0~50 
    Resolution: 0.1 
    Accuracy: 0.1 
    Environment: 
     
    Temperature 
    Operation: 0C~45 
    Transportation and storage: -20C~60C 
    Humidity 
    Operation: 15%~95% (non-condensing) 
    Transportation and storage: 10%~95% (non-condensing) 
    Altitude 
    Operation: 86kPa ~ 106kPa 
    Transportation and storage: 50kPa~106kPa 
     
    Power Requirements: 
    AC power adaptor 
    Input: AC 100~240V 50/60Hz 0.7A 
    Output: 5V 2.5A 
    Internal battery 
    Type: 2.8A build-in Li-ion rechargeable battery 
    Operating Time: 5 hours of stand-by time with a full battery. 
    Recharge time: 8 hours 
     
    Dimension: 280mm × 190mm × 100mm 
    Net Weight: 1000g
     

Related items