MD-200 Analog SpO2 module
SpO2 Module Compatible with BCI (probe & Transfer Protocol ),high accuracy and small in size
Read More SpO2 Module Compatible with BCI (probe & Transfer Protocol ),high accuracy and small in size
Small size and easy installation; reliability high accuracy
Enhanced signal processing capabilities reduced per-fusion of human movement and the impact of weak
Applicable to adults infants and young children and newborn
Operating voltage 3.3 v Low-Voltage
Can display maps and pulse oxygen column
Transfer Protocol BCI compatible
Compatible with BCI probe
Oxygen saturation BF – type
Power Requirements
Operating voltage 5V ±0.1V DC
Power 40mA
Environmental conditions
Operating temperature 5-50℃
Storage temperature -20℃ - +70 ℃
Relative humidity 0-85% (non-condensing)
Size 40 x 52 x 10mm
SPO2
Measuring range 50 -100% SPO2
Measurement accuracy ±2 @ 50-100% SPO2
Less than 50% have not been defined
Pulse rate
Measuring range 30-235 times / min
Measurement accuracy Greater than ±2 times / min or ±2%
Bar chart 0-8
Serial transmission logic capacity TTL/RS232 Serial Port
Standards
IEC60601-1 SPO2: BF-type
IEC60601-1-27: 1994 EN865
ANSI/AAMI SP10: 1992 EN12470-4:2001
ANSI/AAMI EC 13-92
Transfer Protocol BCI compatible. Compatible with BCI probe
Options:
SpO2 Cable (New born)
SpO2 Cable (New born)
SpO2 Cable (Adult finger clip)
SpO2 Cable (Child finger clip)
SpO2 Cable (adult soft tip)
SpO2 Cable (Child soft tip)
SpO2 Cable (nfant soft tip)
SpO2 Cable (Neonate silicone wrap)
SpO2 Cable (multi-site Y type)
SpO2 Cable (with separate wrap)
SpO2 Cable (adult ear clip)
SpO2 Cable (veterinary tongue clip)
SpO2 Cable (multi-site clip)
SpO2 Cable (adult Forehead)
SpO2 Cable (multi-site Y type with foam wrap)
PC Connector (RS232)
USB Power Supplier
USB Power Supplier
Female SpO2 Socket
Product Features
Small size and easy installation; reliability high accuracy
Enhanced signal processing capabilities reduced per-fusion of human movement and the impact of weak
Applicable to adults infants and young children and newborn
Operating voltage 3.3 v Low-Voltage
Can display maps and pulse oxygen column
Transfer Protocol BCI compatible
Compatible with BCI probe
Product Specifications
Oxygen saturation BF – type
Power Requirements
Operating voltage 5V ±0.1V DC
Power 40mA
Environmental conditions
Operating temperature 5-50℃
Storage temperature -20℃ - +70 ℃
Relative humidity 0-85% (non-condensing)
Size 40 x 52 x 10mm
SPO2
Measuring range 50 -100% SPO2
Measurement accuracy ±2 @ 50-100% SPO2
Less than 50% have not been defined
Pulse rate
Measuring range 30-235 times / min
Measurement accuracy Greater than ±2 times / min or ±2%
Bar chart 0-8
Serial transmission logic capacity TTL/RS232 Serial Port
Standards
IEC60601-1 SPO2: BF-type
IEC60601-1-27: 1994 EN865
ANSI/AAMI SP10: 1992 EN12470-4:2001
ANSI/AAMI EC 13-92
Transfer Protocol BCI compatible. Compatible with BCI probe