MD-IBP2 Digital NIBP module
Small in size, simple, excellent reliability and ease of installation clinical monitoring of the accuracy;
Excellent reliability and accuracy of clinical monitoring
Small in size, simple, excellent reliability and ease of installation clinical monitoring of the accuracy;
Excellent reliability and accuracy of clinical monitoring
Meditech NIBP Pump low noise ,low energy consumption,also it environmental,the detail information are as follow: more Details: Air pump fore Blood pressure
The latest digital signal processing technology to achieve anti-noise and software algorithms anti-interference by moving arm;
Capable of accomplishing all NIBP measurement items;
Comply with EC safety design;
Comply with all NIBP standard of ANSI/AAMI;
Applies to adults, children and Newborn;
5V/12V single power supply to avoid interference with the digital circuit by the pump;
Fully compatible with the protocol of CAS Non-invasive blood pressure module (NIBP)
MD-IBP2 is a Small Board
NIBP Pump:
1. folw>1.8L/MIN
2. pressure>500 mmHg
3. life>50000times
4. inflation time<10s in 500CC 5.noise<52dB
Measuring range |
Adult: 30 to 255 mmHg systolic blood pressure An average of 20 to 235 mmHg pressure 15 to 220 mmHg diastolic blood pressure Pulse rate of 30 to 240 times / min Newborn: 30 to 135 mmHg systolic blood pressure An average of 20 to 125 mmHg pressure 15 to 110 mmHg diastolic blood pressure Pulse Rate of 40 to 240 times / min |
Measurement time |
Adults: up to more than 120 seconds; Newborn: up to more than 90 seconds; |
Restriction on software over-voltage |
Adult: Less than 290mmHg; Newborns: no more than 145mmHg; |
Protection on hardware over-voltage |
Adult: 300 ±10 mmHg; Newborn: 150 ±4 mmHg; |
Measuring principle | Oscillometry |
Deflation approach | ladder Deflated |
The initial inflation pressure value |
Adult: 150 mmHg; Newborn: 70 mmHg; |
Sensor zero reset | Prior to each measurement |
Resolution | 1 mmHg |
Measurement accuracy |
Maximum average deviation: no more than ± 5 mmHg; maximum standard deviation: less than 8 mmHg; |
Pressure accuracy instructions | ± 3 mmHg |
Leakage | less than 6 mmHg Per minute; |
Electrical performance |
Voltage: 12 VDC (adapt to the corresponding valve), 5 VDC Quiescent current: 80 mA Measurement current: 200 mA inflated current: 600mA |
Environment |
Operating Temperature: 0 to 55 Celsius degrees Storage Temperature: -20 to 65 Celsius degrees Humidity Range: 0 to 95%, non-condenser Operation Altitude: -500 m to 4600 meters Life Span: can operate 100,000 blood pressure measurements |
Size | 12.6 cm x 6.8 cm x 2.8 cm |
Weight: | 180 g |
Options
NIBP Cuff (infant 8 - 14 cm 5/Bag)
NIBP Cuff (infant 8 - 14 cm 5/Bag)
NIBP Cuff (Child 13 - 20 cm 5/Bag)
NIBP Cuff (Small Adult 18 - 26 cm 5/Bag)
NIBP Cuff (Adult 26 - 35 cm 5/Bag)
NIBP Cuff (Adult Long 29 - 38 cm 5/Bag)
NIBP Cuff (Large Adult 32 - 42 cm 5/Bag)
NIBP Cuff (Large Adult Long 35 - 44 cm 5/Bag)
NIBP Cuff (Thigh 42 - 50 cm)
NIBP Tube 150cm
NIBP Tube 150cm
Product Features
The latest digital signal processing technology to achieve anti-noise and software algorithms anti-interference by moving arm;
Capable of accomplishing all NIBP measurement items;
Comply with EC safety design;
Comply with all NIBP standard of ANSI/AAMI;
Applies to adults, children and Newborn;
5V/12V single power supply to avoid interference with the digital circuit by the pump;
Fully compatible with the protocol of CAS Non-invasive blood pressure module (NIBP)
MD-IBP2 is a Small Board
NIBP Pump:
1. folw>1.8L/MIN
2. pressure>500 mmHg
3. life>50000times
4. inflation time<10s in 500CC 5.noise<52dB